Company: Link Technologies
Case No: L13143. Project: 15.70: LinkSOFT Version 15.70
Logged By: Sanjay (Link Technologies) on 16 May 2025 10:42AM
Priority: High
Product: Framework
Group: Software Defect
Time Taken: 5.00 (Weight: 10.00)
Assigned To: Sanjay (Link Technologies)
Circulation: Sanjay, Vineshwar Prasad
Resolve By: Friday, 16 May 2025 04:42 PM [17 days since logged date]
Status: Closed
Subject: Upgrade to 15.61 Error message: String or binary data would be truncated
Summary:    *** Skype Message ***
Hi Sanjay, I'm testing Yees Upgrade as per case E03019 however upgrade fails with an error

String or binary data would be truncated.

EXEC LT_SYS_Utility_RoleMenuAccess_Clean
Audit Notes:
16 May 202510:44AM Comment 1 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 16-05-2025 04:42 PM Time Taken: 5.00 Notes: ETC extended from: 16/05/2025 to 16/05/2025
PART A - Development work for this case has been completed.

1. The change will be available in version: 15.70 and 15.61.250516

2. The following changes were made (Include Database object names, Program classes, and any other relevant information):

  1. Increased the size of Menu Names from 50 to 512

3. Affected Areas:

  1. Upgrade from versions prior to 15.61

4. The issue was caused by:

  1. Custom menus with Length greater than 50 characters caused an issue when upgrading LinkSOFT
  2. This issue will only happen on customers with custom Dataviews

5. Other Relevant Notes
6. Next Step
(Review and System Test (Developer) -> UAT (Quality) -> Documentation): Closure


If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L13143 in the subject line of all emails regarding this issue.

Document size: 2.9 KB
For call complaints, please contact the Managing Director of the company using this form