Company: Link Technologies
Case No: L13143. Project: 15.70: LinkSOFT Version 15.70
Logged By: Sanjay (Link Technologies) on 16 May 2025 10:42AM
Priority: High
Product: Framework
Group: Software Defect
Time Taken: 5.00 (Weight: 10.00)
Assigned To: Sanjay (Link Technologies)
Circulation: Sanjay, Vineshwar Prasad
Resolve By: Friday, 16 May 2025 04:42 PM [525 days since logged date]
Status: Closed
Subject: Upgrade to 15.61 Error message: String or binary data would be truncated
Summary:    *** Skype Message ***
Hi Sanjay, I'm testing Yees Upgrade as per case E03019 however upgrade fails with an error

String or binary data would be truncated.

EXEC LT_SYS_Utility_RoleMenuAccess_Clean
Audit Notes:
16 May 202510:44AM Comment 1 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 16-05-2025 04:42 PM Time Taken: 5.00 Notes: ETC extended from: 16/05/2025 to 16/05/2025
PART A - Development work for this case has been completed.

1. The change will be available in version: 15.70 and 15.61.250516

2. The following changes were made (Include Database object names, Program classes, and any other relevant information):

  1. Increased the size of Menu Names from 50 to 512

3. Affected Areas:

  1. Upgrade from versions prior to 15.61

4. The issue was caused by:

  1. Custom menus with Length greater than 50 characters caused an issue when upgrading LinkSOFT
  2. This issue will only happen on customers with custom Dataviews

5. Other Relevant Notes: 
6. Next Step
(Review and System Test (Developer) -> UAT (Quality) -> Documentation): Closure


If you have any queries regarding this support incident, please email Support@LinkTechnologies.com.au and include the Case No: L13143 in the subject line of all emails regarding this issue.