Company: Link Technologies
Case No: L10240. Project: 11.40: LinkSOFT Version 11.4
Logged By: Rashna (Edge Business Solutions) on 06 Mar 2019 09:25AM
Priority: Medium
Product: Point of Sale
Group: Enhancement
Time Taken: 6.00 (Weight: 6.00)
Version: 11.3.0902
Assigned To: Sanjay (Link Technologies)
Circulation: Rashna, Sanjay
Resolve By: Thursday, 07 March 2019 12:00 AM [2256 days since logged date]
Status: Closed
Subject: Remove transaction type "Repair" from POS as it is not used.
Summary:    

Navigate to  "POS - Transaction - Load Transaction" and dropdown on the "Transaction Type" list. This contains an option for "Repair". Repair is not a function in POS.

Also, can we sort the dropdown in "Alphabetical Order"?

Audit Notes:
06 Mar 201909:25AM Comment 1 by Rashna (Edge Business Solutions) Case 10240 added to project 11.0
13 Mar 201909:39AM Comment 2 by Sanjay (Link Technologies) Assigned To: Rashna (Edge Business Solutions) Followup Date: 13-03-2019 09:39 AM Time Taken: 2.50

Development work for this case has been completed.

The change will be available in version: 11.0.0313

1. The following changes were made(Include Database object names, Program classes and any other relevant information):|

  1. Added sort order to Transaction Type dropdown

2. The issue was caused by:

  1. Functionality not accounted for in the initial design

3. Next Step:

  1. UAT

15 Mar 201907:54AM Comment 3 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 18-03-2019 12:00 AM Time Taken: 2.00
Hi Sanjay
QA Results
Tests carried out according to requirements specified on the case header

Test Results Summary

Table 1 - Summarised list of issues
NoTest DescriptionPass/Fail
1Validate that the "Repair" has been removed a transaction typePass
2Verify that the transaction type is sorted alphabeticallyPass

Environment Details

  1. OS version: Windows Server 2012
  2. Application version: 11.0.0314
  3. Setup: Demo
  4. Server : 10.0.0.14
  5. Database: LINKSOFT_REPORTNOTES

Next Step: for closure


    15 Mar 201903:01PM Comment 4 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 15-03-2019 03:01 PM Time Taken: 1.50
    Thanks Rashna 

    09 Oct 201908:14AM Comment 5 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019
    If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L10240 in the subject line of all emails regarding this issue.

    Document size: 4.3 KB
    For call complaints, please contact the Managing Director of the company using this form