Subject: | User Login Card scan has an additional "Enter" input that causes incorrect functionality in POS. |
Summary: | 1. Explain the issue User Login Card scan has an additional "Enter" input that causes incorrect functionality in POS. 2. Steps to reproduce - Create a User Login Card for admin.
- Log in as the cashier. Cashier does not have access to change Price.
- Load item 01078.
- Click on the price column. The change price form opens.
- Click on the Authentication icon.
- The authentication form open. Scan the card.
- The scan is completed, however, the form reopens.
Refer to the Case 9617 Results for all affected areas. 3. Environment Details - Version: 10 BETA 7
- Setup - Demo
- Server: 10.0.0.10
- Database:LINKSOFT-DEMO-10-RASHNA
|
Audit Notes: | Edited by sanjay on 05/03/19 10:00. Edited by rashna on 08/10/18 11:31. Edited by rashna on 08/10/18 11:01. |
08 Oct 2018 | 11:19AM Comment 1 by Alvis (Link Technologies) Case 9617 added to project 10.0 |
10 Oct 2018 | 02:31PM Comment 2 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 10-10-2018 02:31 PM Time Taken: 1.00 |
| Development work for this case has been completed. The change will be available in version: 10.08 1. The following changes were made(Include Database object names, Program classes and any other relevant information):| - Resolved enter key behaviour
2. The issue was caused by: - Enter key was being used previously for scanners that did not have enter key at the end of a scan
3. Next Step - UAT
|
|
10 Oct 2018 | 04:08PM Comment 3 by Sanjay (Link Technologies) Assigned To: Rashna (Edge Business Solutions) Followup Date: 10-10-2018 04:08 PM Time Taken: 1.00 |
| System test completed. Proceed with UAT. |
|
11 Oct 2018 | 09:59AM Comment 4 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 11-10-2018 09:59 AM Time Taken: 1.00 |
| Hi Sanjay QA Results Tests carried out according to requirements specified on the case header Test Results Summary Table 1 - Summarised list of issues
Environment Details - OS version: Windows Server 2012
- Application version: 10 Beta
- Setup: Demo
- Server : 10.0.0.10
- Database: LINKSOFT-DEMO-10-RASHNA
Steps to reproduce failed scenarios: N/A Next Step: for closure
|
|
11 Oct 2018 | 10:20AM Comment 5 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 11-10-2018 10:20 AM |
| Thanks Rashna |
|
09 Oct 2019 | 08:14AM Comment 6 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019 |