Company: Link Technologies
Case No: L09617. Project: 10.10: LinkSOFT Version 10.1
Logged By: Rashna (Edge Business Solutions) on 08 Oct 2018 11:31AM
Priority: High
Product: Point of Sale
Group: Software Defect
Time Taken: 3.00 (Weight: 3.00)
Version: 10.155.0117
Assigned To: Sanjay (Link Technologies)
Circulation: Alvis, Development, Rashna, Sanjay, Vineet
Resolve By: Tuesday, 09 October 2018 12:00 AM [2025 days since logged date]
Status: Closed
Subject: User Login Card scan has an additional "Enter" input that causes incorrect functionality in POS.
Summary:    
1. Explain the issue

User Login Card scan has an additional "Enter" input that causes incorrect functionality in POS. 

2. Steps to reproduce
  1. Create a User Login Card for admin.
  2. Log in as the cashier. Cashier does not have access to change Price.
  3. Load item 01078.
  4. Click on the price column. The change price form opens.
  5. Click on the Authentication icon.
  6. The authentication form open. Scan the card.
  7. The scan is completed, however, the form reopens.

Refer to the Case 9617 Results for all affected areas.

3. Environment Details
  • Version: 10 BETA 7
  • Setup - Demo
  • Server: 10.0.0.10
  • Database:LINKSOFT-DEMO-10-RASHNA


Audit Notes:Edited by sanjay on 05/03/19 10:00. Edited by rashna on 08/10/18 11:31. Edited by rashna on 08/10/18 11:01. 
08 Oct 201811:19AM Comment 1 by Alvis (Link Technologies) Case 9617 added to project 10.0
10 Oct 201802:31PM Comment 2 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 10-10-2018 02:31 PM Time Taken: 1.00
Development work for this case has been completed.
The change will be available in version: 10.08

1. The following changes were made(Include Database object names, Program classes and any other relevant information):|

  1. Resolved enter key behaviour

2. The issue was caused by:

  1. Enter key was being used previously for scanners that did not have enter key at the end of a scan

    3. Next Step

    1. UAT

    10 Oct 201804:08PM Comment 3 by Sanjay (Link Technologies) Assigned To: Rashna (Edge Business Solutions) Followup Date: 10-10-2018 04:08 PM Time Taken: 1.00
    System test completed. Proceed with UAT.

    11 Oct 201809:59AM Comment 4 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 11-10-2018 09:59 AM Time Taken: 1.00
    Hi Sanjay
    QA Results
    Tests carried out according to requirements specified on the case header

    Test Results Summary

    Table 1 - Summarised list of issues
    NoTest DescriptionPass/Fail
    1Test passed as per Case 9617 results sheet.Passed

    Environment Details

    1. OS version: Windows Server 2012
    2. Application version: 10 Beta 
    3. Setup: Demo
    4. Server : 10.0.0.10
    5. Database: LINKSOFT-DEMO-10-RASHNA

    Steps to reproduce failed scenarios: N/A

    Next Step: for closure


      11 Oct 201810:20AM Comment 5 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 11-10-2018 10:20 AM
      Thanks Rashna

      09 Oct 201908:14AM Comment 6 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019
      If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L09617 in the subject line of all emails regarding this issue.

      Document size: 4.7 KB
      For call complaints, please contact the Managing Director of the company using this form