Company: Link Technologies
Case No: L09234. Project: 09.40: LinkSOFT Version 9.4
Logged By: Alvis (Link Technologies) on 28 Mar 2018 02:29PM
Priority: High
Product: Framework
Group: Software Defect
Time Taken: 4.00 (Weight: 4.00)
Version: 9.496.1128
Assigned To: Sanjay (Link Technologies)
Circulation: Alvis, Development, Rashna, Sanjay
Resolve By: Wednesday, 28 March 2018 12:00 AM [2220 days since logged date]
Status: Closed
Subject: Report Email created from Report schedule process has incorrect username
Summary:    Report Email created from Report schedule process has the username as NULL.
Audit Notes:
28 Mar 201802:29PM Comment 1 by Alvis (Link Technologies) Case 9234 added to project 9.4
05 Apr 201802:56PM Comment 2 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 05-04-2018 02:56 PM Time Taken: 2.00
This has been resolved in 9.4.

02 May 201804:05PM Comment 3 by Sanjay (Link Technologies) Assigned To: Rashna (Edge Business Solutions) Followup Date: 02-05-2018 04:05 PM Time Taken: 1.00

System test completed.

Verified the following:

  1. Created a report schedule for "SYS User access report"
  2. Verified the Trace and confirm that Username was correctly populated.

Regards
Alvis

SQL Trace is shown below:



03 May 201802:48PM Comment 4 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 04-05-2018 12:00 AM Time Taken: 1.00

Hi Sanjay, 

This case has been successfully tested.

Documentation updated under BI -- Report Schedule

Test Environment

  • Version 9400 Beta 1
  • Database  - LINKSOFT on QA1
  • Application on QA1
  • OS - Windows 7

Test Plan

Test NoDescriptionStatus
1Schedule the 'SYS User Role Menu Access".Set the "Run Report as user" as Alvis. Report should be emailed without errors.Pass
2Email Log should be updated with user created as "Alvis"Pass
3Report Run user should be updated with user as "Alvis"Pass

Figure 1: Email Log


Figure 2: Report Output



07 May 201806:14PM Comment 5 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 07-05-2018 06:14 PM
Thanks Rashna.

09 Oct 201908:14AM Comment 6 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019
If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L09234 in the subject line of all emails regarding this issue.

Document size: 3.2 KB