Company: Link Technologies
Case No: L09436. Project: 10.10: LinkSOFT Version 10.1
Logged By: Alvis (Link Technologies) on 16 Jul 2018 03:57PM
Priority: Low
Product: Framework
Group: Software Defect
Time Taken: 0.00
Version: 10.155.0117
Assigned To: Sanjay (Link Technologies)
Circulation: Alvis, Development, Sanjay
Resolve By: Monday, 16 July 2018 12:00 AM [2110 days since logged date]
Status: Closed
Subject: Business intelligence report timer does not reset
Summary:    

Business intelligence report timer does not reset when there is an error in the reporting procedure.

Steps to reproduce:

  1. Add a raiserror on the report procedure
  2. Run the report - report should show the error under the report selection
  3. Remove raiserror and rerun the report. - Report timer continues when the report is finished.
Audit Notes:Edited by sanjay on 26/11/19 08:49. Edited by sanjay on 05/03/19 10:32. 
16 Jul 201803:57PM Comment 1 by Alvis (Link Technologies) Case 9436 added to project 09.5
21 Aug 201804:36PM Comment 2 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 21-08-2018 04:36 PM
Development work for this case has been completed.
The change will be available in version: 95

1. The following changes were made(Include Database object names, Program classes and any other relevant information):|

  1. Added try-catch block to report viewer

2. The issue was caused by:

  1. Missing Try-Catch Block

    3. Next Step

    1. Not Required

    09 Oct 201908:14AM Comment 3 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019
    If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L09436 in the subject line of all emails regarding this issue.