Subject: | Review and Remove "barcode end marker" configuration |
Summary: | Review and Remove "barcode end marker" configuration which was used for scanners that did not have "enter key" capability. The following areas use "barcode end marker": - Customer search - search box keypress
- Product Maintenance - Part No keypress
- Price Check - Barcode keypress
- POS processing - Barcode keypress
|
Audit Notes: | Edited by sanjay on 05/03/19 09:49. Edited by alvis on 11/10/18 09:38. Edited by alvis on 11/10/18 09:24. |
11 Oct 2018 | 08:43AM Comment 1 by Alvis (Link Technologies) Case 9621 added to project 10.0 |
11 Oct 2018 | 09:38AM Comment 2 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 11-10-2018 09:38 AM Time Taken: 2.00 |
| Development work for this case has been completed. The change will be available in version: 10 beta9 1. The following changes were made(Include Database object names, Program classes and any other relevant information):| - Removed configuration "Barcode End Mark"
- Removed "barcode end mark" functionality from the following areas:
- Customer search - search box keypress
- Product Maintenance - Part No keypress
- Price Check - Barcode keypress
- POS processing - Barcode keypress
2. The issue was caused by: - Change Request
3. Next Step - UAT
|
|
11 Oct 2018 | 10:10AM Comment 3 by Sanjay (Link Technologies) Assigned To: Rashna (Edge Business Solutions) Followup Date: 11-10-2018 10:10 AM Time Taken: 1.00 |
| System test completed. proceed with UAT. |
|
11 Oct 2018 | 11:03AM Comment 4 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 11-10-2018 11:03 AM Time Taken: 1.00 |
| Hi Sanjay QA Results Tests carried out according to requirements specified on the case header Test Results Summary Table 1 - Summarised list of issues No | Test Description | Pass/Fail | 1 | Validate that "Barcode End Mark" is removed from the configuration | Pass | 2 | Validate the below fields are populated with the enter key. - Customer search - search box keypress
- Product Maintenance - Part No keypress
- Price Check - Barcode keypress
- POS processing - Barcode keypress
| Pass |
Environment Details - OS version: Windows Server 2012
- Application version: 10 Beta 8
- Setup: Demo
- Server : 10.0.0.10
- Database: LINKSOFT-DEMO-10-RASHNA
Steps to reproduce failed scenarios: N/A Note: Removed configuration from the documentation. Next Step: for closure
|
|
11 Oct 2018 | 11:48AM Comment 5 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 11-10-2018 11:48 AM |
| Thanks Rashna |
|
09 Oct 2019 | 08:14AM Comment 6 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019 |