Company: Link Technologies
Case No: L12610. Project: 13.11: LinkSOFT version 13.11 - Improvements and Stabilisation
Logged By: Sanjay (Link Technologies) on 01 Oct 2021 08:57AM
Priority: Low
Product: Framework
Group: Software Defect
Time Taken: 7.00 (Weight: 7.00)
Version: 13.11.1021
Assigned To: Development
Circulation: Development, Sanjay
Resolve By: Wednesday, 06 October 2021 11:59 PM [938 days since logged date]
Status: Closed
Subject: Report Notes not updating - should see timestamp value in Report Maintenance
Summary:    When "Report Notes" are updated in menu "Business Intelligence ~> Reports", the note is not updated in menu "Business Intelligence ~> Report Maintenance"
Audit Notes:Edited by sanjay on 19/10/21 10:56. Edited by sanjay on 19/10/21 10:52. Edited by sanjay on 18/10/21 15:48. Edited by sanjay on 18/10/21 15:47. Edited by sanjay on 18/10/21 15:36. Edited by sanjay on 18/10/21 13:30. 
12 Oct 202109:03AM Comment 1 by Sanjay (Link Technologies) Case L12610 added to project 13.11
18 Oct 202101:30PM Comment 2 by Sanjay (Link Technologies) Case L12610 added to project 13.1X
18 Oct 202103:37PM Comment 3 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 20-10-2021 03:36 PM Time Taken: 4.00
PART A - Development work for this case has been completed.

1. The change will be available in version:13.11.1018

2. The following changes were made(Include Database object names, Program classes, and any other relevant information):

  1. Corrected update process to update audit notes

3. Affected Areas:

  1. Report Notes Update forms

4. The issue was caused by:

  1. System Issue not properly accounted for in Audit Processing.

5. Other Relevant Notes
6. Next Step
(Review and System Test (Developer) -> UAT (Quality) -> Documentation): UAT


18 Oct 202103:47PM Comment 4 by Sanjay (Link Technologies) ETC was changed from 06/10/2021 to 06/10/2021
19 Oct 202110:52AM Comment 5 by Sanjay (Link Technologies) Case L12610 added to project 13.11
21 Oct 202102:36PM Comment 6 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 27-10-2021 04:29 PM Time Taken: 3.00
The following tests were performed:

Table 1 - Test Results
#Test Case DetailsPass/FailComments
 1Edit Report Notes for Report Name: Training Report and verify timestamp changes in the menu: "Business Intelligence ~> Report Maintenance"
Pass

 2 Edit Report Notes for Report Name: Training Plan Report and verify timestamp changes in the menu: "Business Intelligence ~> Report MaintenancePass
 
 3   
 4   

Environment Details

  1. OS version: Win10
  2. Application version: 13.11
  3. Setup on:
    1. Server: LinkQA4
    2. Database:
    3. LinkSOFT URL: HTTP://
  4. Login Details: Standard username and password for user "admin"

Next Step: Closure


If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L12610 in the subject line of all emails regarding this issue.

Document size: 8.8 KB
For call complaints, please contact the Managing Director of the company using this form