Company: Link Technologies
Case No: L09684. Project: 10.10: LinkSOFT Version 10.1
Logged By: Alvis (Link Technologies) on 01 Nov 2018 10:20AM
Priority: High
Product: Payroll & HR
Group: Enhancement
Time Taken: 3.00 (Weight: 3.00)
Version: 10.155.0117
Assigned To: Sanjay (Link Technologies)
Circulation: Alvis, Development, Rashna, Sanjay
Resolve By: Thursday, 01 November 2018 12:00 AM [1975 days since logged date]
Status: Closed
Subject: Display employee name on Timesheet Import ~> Timesheet grid
Summary:    Display employee name on Timesheet Import ~> Timesheet grid 
Audit Notes:Edited by sanjay on 05/03/19 09:18. 
01 Nov 201810:20AM Comment 1 by Alvis (Link Technologies) Case 9684 added to project 10.0
01 Nov 201810:30AM Comment 2 by Sanjay (Link Technologies) Assigned To: Rashna (Edge Business Solutions) Followup Date: 01-11-2018 10:30 AM Time Taken: 2.00
Development work for this case has been completed.
The change will be available in version: 10.1.1.0

1. The following changes were made(Include Database object names, Program classes and any other relevant information):|

  1. Added Employee name to Timesheet Grid

2. The issue was caused by:

  1. NA

    3. Next Step

    1. UAT

    01 Nov 201811:23AM Comment 3 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 01-11-2018 11:23 AM Time Taken: 1.00
    Hi Sanjay
    QA Results
    Tests carried out according to requirements specified on the case header

    Test Results Summary

    Table 1 - Summarised list of issues
    NoTest DescriptionPass/Fail
    1Created a time for employee E001. Confirmed employee name appears on the grid.Pass

    Figure 1: Employee Name

    Environment Details

    1. OS version: Windows 7
    2. Application version: 10 Beta 4
    3. Setup: Demo
    4. Server : 10.0.0.10
    5. Database: RASHNA-LINKSOFT-DEMO-10

    Steps to reproduce failed scenarios: N/A

    Next Step: for closure


      01 Nov 201802:31PM Comment 4 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 01-11-2018 02:31 PM
      Thanks Rashna

      09 Oct 201908:14AM Comment 5 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019
      If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L09684 in the subject line of all emails regarding this issue.

      Document size: 16.2 KB
      For call complaints, please contact the Managing Director of the company using this form