Subject: | ESC button not functional on all the Reports in Link Reporter under HR Module (Menu 400) in LINKSOFT New Database |
Summary: | Hi Sanjay,
I have tested the ESC button in Link Reporter on all the reports under HR module and it is not functional. It closes the search screen with a mouse click on Close [Esc] but doesn't with the ESC button on keyboard. Kindly refer to the following image:
Figure 1 - Position Listing Report
Steps to replicate Issue- Log in Link Bacloffice
- Go to Menu 419-1 Position Listing/Occupancy Report
- Select the following:
> 1 - Unfilter Date From > 2 - Set Date To as current date > 3 - Click on details button for Company* > 4 - Click F4 button (Functional) > 5 - Press esc button on keyboard (Not Functional) > 5 - Select Close [Esc] button with mouse click (Functional)
Please if you could address this.
Regards, Fariha |
Audit Notes: | |
06 Mar 2018 | 09:57AM Comment 1 by Alvis (Link Technologies) Case 9183 added to project 9.2 |
06 Mar 2018 | 10:03AM Comment 2 by Sanjay (Link Technologies) Assigned To: Fariha Kauser Tafsil (Link Fiji) Followup Date: 06-03-2018 10:03 AM |
| Hi Fariha, Can you explain the issue as I am not able to understand what you are trying to do? regards Alvis |
|
06 Mar 2018 | 11:13AM Comment 3 by Fariha Kauser Tafsil (Link Fiji) Assigned To: Alvis (Link Technologies) Followup Date: 06-03-2018 11:13 AM Time Taken: 1.00 |
| Hi Alvis,
I have update the case header with detailed information.
Regards, Fariha |
|
06 Mar 2018 | 11:22AM Comment 4 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 06-03-2018 11:22 AM Time Taken: 1.00 |
| The issue was caused by: ESC button not tagged to the CLOSE button. The issue has been corrected in 9.2.10. |
|
06 Mar 2018 | 04:54PM Comment 5 by Sanjay (Link Technologies) Assigned To: Rashna (Edge Business Solutions) Followup Date: 06-03-2018 04:54 PM |
| System test completed. Please proceed with UAT. |
|
07 Mar 2018 | 01:04PM Comment 6 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 08-03-2018 12:00 AM Time Taken: 1.00 |
| Hi Sanjay, This case has been tested. Please review and close. Thanks Rashna.
QA Results Tests carried out according to requirements specified on the case header Test Results Summary Table 1 - Summarised list of issues No | Test Description | Pass/Fail | 1 | F4 should load the selection list | Pass | 2 | ESC should close the search form. | Pass |
Environment Details - OS version:Windows 7
- Application version:9.3.0
- Database (Demo/New/Client): LINKSOFT_NEW on QA4
Steps to reproduce failed scenarios:
|
|
07 Mar 2018 | 03:02PM Comment 7 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 07-03-2018 03:02 PM |
| Thanks Rashna |
|
09 Oct 2019 | 08:14AM Comment 8 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019 |