Company: Link Technologies
Case No: L09674. Project: 10.10: LinkSOFT Version 10.1
Logged By: Rashna (Edge Business Solutions) on 25 Oct 2018 03:18PM
Priority: High
Product: Payroll & HR
Group: Software Defect
Time Taken: 7.00 (Weight: 7.00)
Version: 10.155.0117
Assigned To: Sanjay (Link Technologies)
Circulation: Alvis, Development, Rashna, Sanjay
Resolve By: Friday, 26 October 2018 12:00 AM [2010 days since logged date]
Status: Closed
Subject: Previous records are appearing in the data field if an invalid code is used for search
Summary:    

Issue: Previous records are appearing in the data field if an invalid code is used for search

Version 10.1.6

Affected Screens

  • 316-3
  • 316-5
  • 316-8
  • 322
  • 326
  • 332-3
  • 334-2
  • 402
  • 421
  • 429
  • 437-1
  • 452
  • 453
  • 454-2
  • 455
  • 456
  • 471-1-4
  • 471-2-2
  • 495
  • 520-1 - Detail is not removed from the screen
  • 524-1 -  Detail is not removed from the screen
  • 524-3 -  Detail is not removed from the screen
Audit Notes:Edited by sanjay on 26/11/19 08:12. Edited by sanjay on 05/03/19 09:04. Edited by rashna on 25/10/18 15:18. Edited by rashna on 25/10/18 15:17. Edited by rashna on 25/10/18 15:14. Edited by rashna on 25/10/18 15:04. Edited by rashna on 25/10/18 14:59. 
25 Oct 201802:52PM Comment 1 by Rashna (Edge Business Solutions) Case 9674 added to project 10.0
26 Oct 201809:16AM Comment 2 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 26-10-2018 09:16 AM Time Taken: 2.00
Development work for this case has been completed.
The change will be available in version: 10.1.0.6

1. The following changes were made(Include Database object names, Program classes and any other relevant information):|

  1. Changed all back-office screens that contain a side panel search to reset the data when side panel result is empty

2. The issue was caused by:

  1. Data was not reset when side panel search was empty

    3. Next Step

    1. UAT

    29 Oct 201809:55AM Comment 3 by Rashna (Edge Business Solutions) Assigned To: Alvis (Link Technologies) Followup Date: 29-10-2018 09:55 AM Time Taken: 2.00

    Hi Alvis, 

    I have tested the case as per the test plan.

    The following menus have failed

    • 430
    • 431
    • 432
    • 433
    • 434
    • 435
    • 471-1-4

    Thanks
    Rashna


    30 Oct 201808:10AM Comment 4 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 30-10-2018 08:10 AM Time Taken: 2.00
    Development work for this case has been completed.
    The change will be available in version: 10.1.0.8

    1. The following changes were made(Include Database object names, Program classes and any other relevant information):|

    1. Corrected the screens to reset the data when the search panel is empty

    2. The issue was caused by:

    1. Data was not being reset on the empty search screen.

      3. Next Step

      1. UAT

      31 Oct 201808:50AM Comment 5 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 31-10-2018 08:50 AM Time Taken: 1.00
      Hi Sanjay
      QA Results
      Tests carried out according to requirements specified on the case header

      Test Results Summary

      Table 1 - Summarised list of issues
      NoTest DescriptionPass/Fail
      1

      Tested below screens

      • 430
      • 431
      • 432
      • 433
      • 434
      • 435
      • 471-1-4
      Pass

      Environment Details

      1. OS version: Windows Server 2012
      2. Application version: 10.1.0.8
      3. Setup: Demo
      4. Server : 10.0.0.10
      5. Database:RASHNA-LINKSOFT-DEMO-10

      Steps to reproduce failed scenarios: N/A

      Next Step: for closure


        01 Nov 201809:06AM Comment 6 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 01-11-2018 09:06 AM
        Thanks Rashna

        09 Oct 201908:14AM Comment 7 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019