Company: Link Technologies
Case No: L09654. Project: 10.10: LinkSOFT Version 10.1
Logged By: Rashna (Edge Business Solutions) on 19 Oct 2018 11:50AM
Priority: High
Product: Payroll & HR
Group: Software Defect
Time Taken: 4.00 (Weight: 4.00)
Version: 10.155.0117
Assigned To: Sanjay (Link Technologies)
Circulation: Alvis, Development, Rashna, Sanjay
Resolve By: Thursday, 18 October 2018 12:00 AM [2015 days since logged date]
Status: Closed
Subject: Resetting or changing the password of a user at HQ does not allow the user to login at the Branch.
Summary:    

Issue: Resetting or changing the password of a user at HQ does not allow the user to login at the Branch.

Reset the password of the cashier at HQ.
Log in with the password at Branch this is not allowed.
Cashier is able to login with the password at the HQ

Test Plan

Audit Notes:Edited by sanjay on 05/03/19 10:01. Edited by rashna on 19/10/18 11:50. 
19 Oct 201810:53AM Comment 1 by Rashna (Edge Business Solutions) Case 9654 added to project 10.0
19 Oct 201811:17AM Comment 2 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 19-10-2018 11:17 AM Time Taken: 2.00
Development work for this case has been completed.
The change will be available in version: 10.0.9.6

1. The following changes were made(Include Database object names, Program classes and any other relevant information):|

  1. Added the following tables that are required for user security and login to replication configuration:
    1. aspnet_users
    2. aspnet_membership
    3. aspnet_roles
    4. aspnet_usersinroles
    5. LT_SYS_User
    6. LT_SYS_UserCompany
    7. LT_SYS_UserWorkflow
    8. LT_SYS_RoleMenuAccess
    9. LT_POS_UserLocationMapping

2. The issue was caused by:

  1. User management is moved to aspnet security framework. These tables were not included in the replication.

    3. Next Step

    1. UAT

    22 Oct 201808:09AM Comment 3 by Sanjay (Link Technologies) Assigned To: Rashna (Edge Business Solutions) Followup Date: 22-10-2018 08:09 AM
    For UAT

    23 Oct 201810:26AM Comment 4 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 23-10-2018 10:26 AM Time Taken: 2.00
    Hi Sanjay
    QA Results
    Tests carried out according to requirements specified on the case header

    Test Results Summary

    Table 1 - Summarised list of issues
    NoTest DescriptionPass/Fail
    1This case has been successfully tested as per the test planPass

    Environment Details

    1. OS version: Windows Server 2012
    2. Application version: 10.10
    3. Setup: Demo
    4. Server : 10.0.0.10
    5. Database: RASHNA-LINKSOFT-10-HQ and RASHNA-LINKSOFT-10-BRANCH

    Steps to reproduce failed scenarios: N/A

    Next Step: for closure


      24 Oct 201808:41AM Comment 5 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 24-10-2018 08:41 AM
      Thanks Rashna 

      09 Oct 201908:14AM Comment 6 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019
      If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L09654 in the subject line of all emails regarding this issue.

      Document size: 4.3 KB
      For call complaints, please contact the Managing Director of the company using this form