Subject: | Unable to search employees on the "Training Plan" menu. The Cursor is redirected. |
Summary: | Issue: Unable to search employees on the "Training Plan" menu. The Cursor is redirected.
Steps to Replicate- Open menu 493.
- Enter "S" in the Employee Filter field.
- The cursor moves to the Search for training codes.
|
Audit Notes: | Edited by sanjay on 26/11/19 08:15. Edited by sanjay on 05/03/19 09:05. |
12 Oct 2018 | 11:42AM Comment 1 by Rashna (Edge Business Solutions) Case 9633 added to project 10.0 |
12 Oct 2018 | 02:17PM Comment 2 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 12-10-2018 02:17 PM Time Taken: 1.00 |
| Development work for this case has been completed. The change will be available in version: 10.10 1. The following changes were made(Include Database object names, Program classes and any other relevant information):| - Corrected focus retainment when searching in employee filter
2. The issue was caused by: - The field focus was lost on search
3. Next Step - UAT
|
|
12 Oct 2018 | 04:39PM Comment 3 by Sanjay (Link Technologies) Assigned To: Rashna (Edge Business Solutions) Followup Date: 12-10-2018 04:39 PM Time Taken: 1.00 |
| System test completed. Proceed with UAT. |
|
15 Oct 2018 | 07:33AM Comment 4 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 15-10-2018 07:33 AM Time Taken: 1.00 |
| Hi Sanjay QA Results Tests carried out according to requirements specified on the case header Test Results Summary Table 1 - Summarised list of issues No | Test Description | Pass/Fail | 1 | Search for employee "Grant Allan Clyde". This should be successful. | Pass |
Environment Details - OS version: Windows Server 2012
- Application version: 10 Beta 9
- Setup: Demo
- Server : 10.0.0.10
- Database: LINKSOFT-DEMO-10-RASHNA
Steps to reproduce failed scenarios: N/A Next Step: for closure
|
|
15 Oct 2018 | 03:11PM Comment 5 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 15-10-2018 03:11 PM |
| Thanks Rashna |
|
09 Oct 2019 | 08:14AM Comment 6 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019 |