Company: Link Technologies
Case No: L09429. Project: 09.40: LinkSOFT Version 9.4
Logged By: Rashna (Edge Business Solutions) on 13 Jul 2018 10:08AM
Priority: High
Product: Point of Sale
Group: Software Defect
Time Taken: 6.00 (Weight: 6.00)
Version: 9.496.1128
Assigned To: Sanjay (Link Technologies)
Circulation: Alvis, Development, Rashna, Sanjay
Resolve By: Saturday, 14 July 2018 12:00 AM [2113 days since logged date]
Status: Closed
Subject: The cursor moves to the first field when updating the BIN in the Product Matrix
Summary:    

Hi Sanjay

Issue: The cursor jumps to the first field when updating the BIN in the Product Matrix. This is an issue with Adjustments, Purchasing, Stock Take and Transfer

Steps to Replicate

  1. Create the Product Matrix as below
    1. Code - LEN ,Description - Length and details as 50cm,60cm and 15cm.
    2. Code - WID , Description - Width and details as 30cm, 40cm and 15cm.
  2. Create a Product as R1001 - Photo Frame. Row Matrix = Length and Column Matrix = Width.
  3. Create an adjustment for the product. Quantity = 5 and Cost = $15
  4. In the details, Enter quantity for matrix 15cm to 15cm as 1. Select BIN as A-1
  5. Select the Length as 60cm and Width as 40cm, double-click and select the BIN. This takes the cursor to the first matrix of 15cm by 15cm. If the user saves the record. BIN is updated for 15cm by 40cm Matrix.

Test Environment

  • Version 9480 Beta 10
  • LINKSOFTBETA10 on QA1 - Demo Setup
  • Product R1001

Thanks

Rashna

Audit Notes:
13 Jul 201808:01AM Comment 1 by Alvis (Link Technologies) Case 9429 added to project 09.4
13 Jul 201802:36PM Comment 2 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 13-07-2018 02:36 PM Time Taken: 4.00
Development work for this case has been completed.
The change will be available in version: 9.4.8.12

1. The following changes were made(Include Database object names, Program classes and any other relevant information):|

  1. The following changes are made on the following screens: 
    1. Inventory Adjustment
    2. Stocktake
    3. transfer request
    4. transfer ship
    5. transfer receive
    6. requisition entry
    7. purchase order entry
    8. purchase order receive
  2. Changed the product matrix data update to happen when the user clicks on save button or clicks on the different row in the left panel.
  3. The total quantity is updated when the data is saved
  4. On Save, the screen stays open. The user can click on the X to close the screen.

2. The issue was caused by:

  1. When data was saved on each row change, the cursor moved to the first record.

    3. Next Step

    1. UAT

    13 Jul 201804:01PM Comment 3 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 13-07-2018 04:01 PM
    Please proceed with UAT on 94.012

    16 Jul 201809:09AM Comment 4 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 17-07-2018 12:00 AM Time Taken: 2.00

    Hi Sanjay, 

    This case has been successfully tested.

    Documentation is not required for the case.

    Test Plan

    1. Test the product matrix on following screens to verify that the cursor positionings are correct - Pass
      1. Inventory Adjustment
      2. Stocktake
      3. transfer request
      4. transfer ship
      5. transfer receive
      6. requisition entry
      7. purchase order entry
      8. purchase order receive
    2. Verify that 519 and the following reports are correctly updated - Pass. Refer to figure 1 for test details
      1. Inventory Movement
      2. Inventory Listing
    Figure 1: Test Details


    Test Environment 
    • Version 948 Beta 12
    • LINKSOFT on QA1 - Demo Setup 

    Thanks Rashna



    16 Jul 201811:10AM Comment 5 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 16-07-2018 11:10 AM
    Thanks Rashna

    09 Oct 201908:14AM Comment 6 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019
    If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L09429 in the subject line of all emails regarding this issue.

    Document size: 3.8 KB
    For call complaints, please contact the Managing Director of the company using this form