Subject: | Make "App User" read-only in Connectivity Setting in POS and Reporter. |
Summary: | We need an improvement to remove "App User" and "App Password" from Connectivity Setting in POS. This to be only shown in POS config file and not the screen. Justification. Since the setting is accessible by the users, they change the "App User" and "App Password" which causes issues in the system. We experienced a situation where the username and password was changed from Linkadmin to SA in a replication setup. This caused huge amount of data mismatach. Although this was a consulting exercise, it is a tedious task. Client Cases - XXXXX -The user changed the "App User and Password" to use "SA" and "LinkFiji123" on a machine. This caused the data not replicate from that machine. Data was populating at the branch server but not replicating to HQ.
- Lunaeva - A user on a machine, changed the "App User and Password". Users were not able to log in and the client did not have internet access for us to clearly identify what the cause was.
Steps to Replicate - Open POS.
- Crtl Z on the login Page.
|
Audit Notes: | |
21 Mar 2018 | 09:28AM Comment 1 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 21-03-2018 09:28 AM |
| Agreed to make App User read only. |
|
21 Mar 2018 | 09:28AM Comment 2 by Sanjay (Link Technologies) Case 9217 added to project 9.4 |
26 Mar 2018 | 10:16AM Comment 3 by Sanjay (Link Technologies) Assigned To: Alvis (Link Technologies) Followup Date: 26-03-2018 10:16 AM Time Taken: 2.00 |
| Changed POS and Reporter "Server Configuration" so that Username cannot be changed from LinkADMIN. Proceed with System test. You will need updates for POS and REPORTER. |
|
26 Mar 2018 | 04:47PM Comment 4 by Alvis (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 26-03-2018 04:47 PM Time Taken: 0.50 |
| Hi Sanjay, I have verified POS and Reporter connectivity screen. POS is working. Reporter is not working. Please look into this. regards Alvis |
|
27 Mar 2018 | 09:52AM Comment 5 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 27-03-2018 09:52 AM |
| This is working on Reporter as well. Lets system test this on the full build. |
|
01 May 2018 | 10:20AM Comment 6 by Sanjay (Link Technologies) Assigned To: Rashna (Edge Business Solutions) Followup Date: 01-05-2018 10:20 AM Time Taken: 1.00 |
| System test completed. "App User" is read-only in POS and Reporter. |
|
01 May 2018 | 12:43PM Comment 7 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 02-05-2018 12:00 AM Time Taken: 1.00 |
| Hi Sanjay, This case has been successfully tested. Test Environment - Version - 9400
- Database - LINKSOFT on QA1
- Application on QA1
- OS - Windows 7
Test Plan Test No | Description | Status | 1 | Control Z on Link Reporter and "Username" should be greyed out | Pass | 2 | Control Z on Link POS and "Username" should be greyed out
| Pass | 3 | Users should be able to log in the application without errors | Pass |
Thanks Rashna |
|
02 May 2018 | 08:43AM Comment 8 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 02-05-2018 08:43 AM |
| Thanks Rashna |
|
09 Oct 2019 | 08:14AM Comment 9 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019 |