Subject: | Refactor error log to show information and error messages accurately |
Summary: | When leave validation is performed, the status is shown as an error instead of validation. To resolve the issue, use the severity of the raiserror to mark the entry status. Refer to procedure "LT_ESS_SaveLeaveApplication" as an example. |
Audit Notes: | Edited by alvis on 05/10/18 11:41. Edited by alvis on 13/08/18 15:06. |
21 Jun 2018 | 09:30AM Comment 1 by Alvis (Link Technologies) Case 9359 added to project 09.5 |
14 Aug 2018 | 02:58PM Comment 2 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 14-08-2018 02:58 PM Time Taken: 2.00 |
| Development work for this case has been completed. The change will be available in version: 9.5 1. The following changes were made(Include Database object names, Program classes and any other relevant information):| - Changed "leave save" procedure to log the message as validation instead of an error.
2. The issue was caused by: - change request
3. Next Step - UAT
|
|
23 Aug 2018 | 07:40AM Comment 3 by Sanjay (Link Technologies) Assigned To: Rashna (Edge Business Solutions) Followup Date: 23-08-2018 07:40 AM |
| Proceed with UAT using LinkSOFT95BETA2 |
|
27 Aug 2018 | 10:09AM Comment 4 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 27-08-2018 10:09 AM Time Taken: 1.00 |
| Hi Sanjay QA Results Tests carried out according to requirements specified on the case header Test Results Summary Table 1 - Summarised list of issues No | Test Description | Pass/Fail | 1 | Messages when applying for leave should be recorded a "Validation" in Linkweb | Pass |
Figure 1: Leave application validation
Environment Details - OS version: Windows Server 2012
- Application version: 9.5 Beta 2
- Setup: Demo /Client: Demo
- Server : QA4
- Database: LINKSOFT-UAT95-LINKFJ
Steps to reproduce failed scenarios: N/A Next Step: Case assigned to Sanjay for closure. Thanks Rashna |
|
28 Aug 2018 | 09:14AM Comment 5 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 28-08-2018 09:14 AM |
| Thanks Rashna |
|
09 Oct 2019 | 08:14AM Comment 6 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019 |