Company: Link Technologies
Case No: L09232. Project: 09.40: LinkSOFT Version 9.4
Logged By: Sanjay (Link Technologies) on 27 Mar 2018 10:01AM
Priority: Low
Product: Framework
Group: Enhancement
Time Taken: 19.00 (Weight: 19.00)
Version: 9.496.1128
Assigned To: Sanjay (Link Technologies)
Circulation: Alvis, Development, Rashna, Sanjay
Resolve By: Friday, 20 April 2018 12:00 AM [2222 days since logged date]
Status: Closed
Subject: Refresh and standardize ICONS for LinkSOFT Applications
Summary:    

Icons in LinkSOFT application has been used from a nonstandard repository. The purpose of this case is to standardize icons across all applications.

Below is a list of tasks to be completed

  1. Research icons providers for business applications
  2. Provide option to purchase an icon repository that will satisfy the needs of all applications
  3. Icons must have the following properties:
    1. Small footprint
    2. ico, jpg and png formats
    3. have a clear background
    4. Color
    5. Simple format - easy to read on 18  px x 18 px
    6. Full suite of icons with standard names to fit into all menus
  4. Implement changes on PB framework
  5. Implement changes on web framework
  6. Implement changes on DOT NET framework
Audit Notes:
27 Mar 201810:01AM Comment 1 by Sanjay (Link Technologies) Case 9232 added to project 9.4
29 Mar 201803:54PM Comment 2 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 29-03-2018 03:54 PM Time Taken: 16.00

The following changes have been made:

  1. Identified and implemented a standard set of icons from dev express library
  2. changed all web applications to use icons with clear background with 16x16 pixel.

02 May 201804:27PM Comment 3 by Sanjay (Link Technologies) Assigned To: Rashna (Edge Business Solutions) Followup Date: 02-05-2018 04:27 PM Time Taken: 1.00

System test completed.

Verified all Web applications and confirmed that new set of icons are used.


03 May 201811:32AM Comment 4 by Rashna (Edge Business Solutions) Assigned To: Alvis (Link Technologies) Followup Date: 04-05-2018 12:00 AM Time Taken: 1.00

Hi Alvis,

Below is the test results. Refer to item 1 for the issue.

Test Environment.

  • Version 9400.
  • Database - LINKSOFT on QA1
  • Application on QA1
  • OS - Windows

Test Plan

Test NoDescriptionStatus
1ESS should be updated with new icons and the menus should open without errors.Failed. Leave Analysis gives an error. Refer to Figure 1. 
2POS should be updated with new icons and the menus should open without errors
Pass

3

RM should be updated with new icons and the menus should open without errors
Pass

Figure 1: Error 



03 May 201801:23PM Comment 5 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 04-05-2018 12:00 AM Time Taken: 1.00

Hi Sanjay, 

This case is a pass as per comment 4.

Case 9272 - Unable to access the Leave Analysis menu in ESS has been logged for the mentioned issue.

Thanks

Rashna


03 May 201802:36PM Comment 6 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 03-05-2018 02:36 PM
Hi Rashna, this issue has been addressed in another case. I will close this case.

09 Oct 201908:14AM Comment 7 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019
If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L09232 in the subject line of all emails regarding this issue.

Document size: 4.2 KB