Company: Link Technologies
Case No: L08761. Project: 08.20: LinkSOFT Version 8.2
Logged By: Rashna (Edge Business Solutions) on 17 Aug 2017 09:37AM
Priority: High
Product: Point of Sale
Group: Software Defect
Time Taken: 1.00 (Weight: 8.00)
Version: 8.290.0115
Assigned To: Sanjay (Link Technologies)
Circulation: Alvis, Development, Rashna
Resolve By: Friday, 18 August 2017 12:00 AM [2417 days since logged date]
Status: Closed
Subject: "Period" search not working on the "Inventory Valuation Report"
Summary:    

Hi Sanjay,

I have tested the case in 816.

The "Search[F4]" is not working for the "Period" filter on the Inventory Valuation Report.

Steps to Replicate

  1. Load "Inventory Valuation" report.
  2. Run the valuation process.
  3. On the "Period" filter search for Period"2017". Search by description.
  4. System currently loads all the period.


Audit Notes:
21 Aug 201703:28PM Comment 1 by Alvis (Link Technologies) Case 8761 added to project 8.18
05 Sep 201709:01AM Comment 2 by Alvis (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 05-09-2017 09:01 AM
Issue resolved as part of case 8792.

20 Sep 201710:00AM Comment 3 by Rashna (Edge Business Solutions) Assigned To: Rashna (Edge Business Solutions) Followup Date: 20-09-2017 10:00 AM Time Taken: 1.00
QA for product and Patch Releases
Step 1 - Developer to system test changes until not issues are found - Alvis and Sanjay to sign off on System Test
Step 2 - Product expert allocated by Consulting Manager for Product QA.
               Consulting Manager to allocate resource
               Consulting Manager to sign off on UAT and Generic Test

STEP 1 - DETAILS OF QA can be entered in case comments. Summary to be maintained in the table below.

Tested case with 818 Beta 1 in Qa1. Database - LINKSOFT

Table 1 - Summarised list of issues
NoIssue Description Resolved? 
1 The valuation process should successful run to update the periods for the report Pass
2 Users should be able to filter the "Periods" by year and month Pass

Figure 1: Period search by Month


WORKFLOW:

  1. Original case assigned to Development
  2. When the product is ready for release, System test details are entered into comments and the CASE HEADER Table updated.
  3. If system test passes, assign case to Consulting Manager for UAT
  4. If UAT Passes, Assign case for Documentation or close case

    09 Oct 201908:14AM Comment 4 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019