Company: Link Technologies
Case No: L08992. Project: 08.20: LinkSOFT Version 8.2
Logged By: Rashna (Edge Business Solutions) on 20 Dec 2017 02:51PM
Priority: High
Product: Point of Sale
Group: Change Request
Time Taken: 4.00 (Weight: 4.00)
Version: 8.290.0115
Assigned To: Sanjay (Link Technologies)
Circulation: Alvis, Development, Rashna, Sanjay
Resolve By: Thursday, 21 December 2017 12:00 AM [2317 days since logged date]
Status: Closed
Subject: Cost greater than 6 digits is not displayed on the Inventory Movement Summary and Valuation report
Summary:    

Hi Sanjay, 

I have tested the case in QA1 with database LINKSOFT. Version 8.2.3.

Inventory Movement Summary and Valuation report does not display costs that have  more than 6 digits. 

For example

  1. Cost of 100.00 is successfully displayed.
  2. Cost of $1500.00 is not displayed.

We have clients who deal with spare parts which have large cost amounts.

Please increase field size to reflect cost.

Figure 1: Inventory Movement Summary and Valuation report 



Audit Notes:
20 Dec 201701:56PM Comment 1 by Alvis (Link Technologies) Case 8992 added to project 8.2
20 Dec 201702:51PM Comment 2 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 20-12-2017 02:51 PM Time Taken: 3.00

We have increased the cost value as shown below. We will need to change this report to landscape to show larger values.



21 Dec 201707:54AM Comment 3 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 21-12-2017 07:54 AM Time Taken: 1.00
QA Results
Step 1 - Developer will perform test based on test cases provided
Step 2 - Product expert to complete Product QA based on test cases.

Test cases are provided on the case header before the case is approved for development.

Test Results Summary

Table 1 - Summarised list of issues
NoTest Description Pass/Fail 
1
Cost with 6 digits should be successfully displayed on the reportPass
2
Quantity with 6 digits should be successfully displayed on the reportPass
3
Large computations should be successfully output on the reportPass

QA Environment Details

  1. OS version: Windows 7
  2. Application version: 8.2.4
  3. Database (Demo/New/Client): Demo
Figure 1: Sample Output


Steps to reproduce failed scenarios:



      09 Oct 201908:14AM Comment 4 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019