Subject: | "Inventory Gross Profit Listing" report is redundant. |
Summary: | Below are the concerns with the "Inventory Gross Profit Listing" - The details are unclear in the report. There are columns with labels as "N/A".
- The report has similar details to the "Gross Margin Report" - Refer to Case 10185. Thus this report becomes redundant.
Next Step Sanjay and Alvis to review report details and approve removal from the system. |
Audit Notes: | Edited by sanjay on 11/09/19 16:00. |
21 Feb 2019 | 10:49AM Comment 1 by Rashna (Edge Business Solutions) Case 10187 added to project 10.2 |
28 Feb 2019 | 11:38AM Comment 2 by Sanjay (Link Technologies) Assigned To: Alvis (Link Technologies) Followup Date: 28-02-2019 11:38 AM Time Taken: 1.50 |
| Approved for V11 |
|
06 Mar 2019 | 08:24AM Comment 3 by Sanjay (Link Technologies) Assigned To: Rashna (Edge Business Solutions) Followup Date: 06-03-2019 08:24 AM Time Taken: 2.50 |
| Development work for this case has been completed. The change will be available in version: 11.0.0306 1. The following changes were made(Include Database object names, Program classes and any other relevant information):| - Removed "Inventory Gross Profit Listing"
2. The issue was caused by: - Improvement
3. Next Step: - UAT
4. Notes: |
|
06 Mar 2019 | 02:54PM Comment 4 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 07-03-2019 12:00 AM Time Taken: 2.50 |
| Hi Sanjay QA Results Tests carried out according to requirements specified on the case header Test Results Summary Table 1 - Summarised list of issues No | Test Description | Pass/Fail | 1 | Validate that the "Inventory Gross Profit Listing" has been removed from - 221-4
- Report Maintenance
- Role Menu Access
| Pass |
Environment Details - OS version: Windows Server 2012
- Application version: 11.0.0305
- Setup: Demo
- Server : 10.0.0.14
- Database: LINKSOFT_REPORTNOTES
Steps to reproduce failed scenarios: N/A Next Step: for closure
|
|
07 Mar 2019 | 09:02AM Comment 5 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 07-03-2019 09:02 AM Time Taken: 1.50 |
| Thanks Rashna |
|
09 Oct 2019 | 08:14AM Comment 6 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019 |