Company: Link Technologies
Case No: L09357. Project: 09.40: LinkSOFT Version 9.4
Logged By: Rashna (Edge Business Solutions) on 20 Jun 2018 02:19PM
Priority: Medium
Product: Point of Sale
Group: Software Defect
Time Taken: 2.00 (Weight: 2.00)
Version: 9.496.1128
Assigned To: Sanjay (Link Technologies)
Circulation: Alvis, Development, Rashna, Sanjay
Resolve By: Thursday, 21 June 2018 12:00 AM [2135 days since logged date]
Status: Closed
Subject: UOM lookup field is not shaded blue on "Product Master" screen
Summary:    

Hi Sanjay,

UOM is a lookup field on 519, but the field is not shaded as blue. Please make this consistent with the screen.

Figure 1: 519 Fields


Audit Notes:
26 Jun 201803:16PM Comment 1 by Alvis (Link Technologies) Case 9357 added to project 09.5
06 Jul 201802:34PM Comment 2 by Alvis (Link Technologies) Case 9357 removed from project 09.5
06 Jul 201802:35PM Comment 3 by Alvis (Link Technologies) Case 9357 added to project 09.4
06 Jul 201804:31PM Comment 4 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 06-07-2018 04:31 PM Time Taken: 1.00
Development work for this case has been completed.
The change will be available in version: 9.4.8.7

1. The following changes were made(Include Database object names, Program classes and any other relevant information):|

  1. When the new button is clicked, UOM background color is changed to sky blue.

2. The issue was caused by:

  1. The background color was not reset

3. Next Step

  1. UAT

09 Jul 201807:14AM Comment 5 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 10-07-2018 12:00 AM Time Taken: 1.00

Hi Sanjay, 

This case has been successfully tested.

Documentation is not required for the case.

Test Plan

  1. Click on "New" on 519, UOM field should be highlighted as blue to indicate as a lookup field - Pass

Test Environment

  • Version 948 Beta 7
  • LINKSOFT on QA1

Thanks

Rashna 


09 Jul 201810:07AM Comment 6 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 09-07-2018 10:07 AM
Thanks Rashna 

09 Oct 201908:14AM Comment 7 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019
If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L09357 in the subject line of all emails regarding this issue.

Document size: 1.7 KB
For call complaints, please contact the Managing Director of the company using this form