Company: Link Technologies
Case No: L12609. Project: 13.11: LinkSOFT version 13.11 - Improvements and Stabilisation
Logged By: Sanjay (Link Technologies) on 01 Oct 2021 11:30AM
Priority: Low
Product: Framework
Group: Enhancement
Time Taken: 10.00 (Weight: 10.00)
Version: 13.11.1021
Assigned To: Development
Circulation: Development, Sanjay
Resolve By: Wednesday, 06 October 2021 11:59 PM [932 days since logged date]
Status: Closed
Subject: Add Search and limit rows to "Rows to return" configuration as some companies have > 10,000 Accounts Receivable Accounts
Summary:    

Menu: Integration ~> AR Master

Some companies have > 10,000 GL Accounts and this can cause Timeout.

Audit Notes:Edited by sanjay on 19/10/21 10:56. Edited by sanjay on 19/10/21 10:52. Edited by sanjay on 18/10/21 15:47. Edited by sanjay on 18/10/21 15:25. Edited by sanjay on 18/10/21 13:30. 
12 Oct 202109:03AM Comment 1 by Sanjay (Link Technologies) Case L12609 added to project 13.11
18 Oct 202101:30PM Comment 2 by Sanjay (Link Technologies) Case L12609 added to project 13.1X
18 Oct 202103:24PM Comment 3 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 20-10-2021 03:22 PM Time Taken: 6.00
PART A - Development work for this case has been completed.

1. The change will be available in version:13.11.1018

2. The following changes were made(Include Database object names, Program classes, and any other relevant information):

  1. Added "Maximum Rows to return" and a Search filter on the page
  2. Search Filter uses Full-Text Search indexing

3. Affected Areas:

  1. Menu: Integration ~> AR Master

4. The issue was caused by:

  1. Improvement

5. Other Relevant Notes
6. Next Step
 (Review and System Test (Developer) -> UAT (Quality) -> Documentation): UAT


18 Oct 202103:47PM Comment 4 by Sanjay (Link Technologies) ETC was changed from 06/10/2021 to 06/10/2021
19 Oct 202110:52AM Comment 5 by Sanjay (Link Technologies) Case L12609 added to project 13.11
21 Oct 202102:42PM Comment 6 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 27-10-2021 02:41 PM Time Taken: 4.00
The following tests were performed:

Table 1 - Test Results
#Test Case DetailsPass/FailComments
 1Change "Company Administration ~> Configuration" Flag: System.Search.RowsToReturn = 100. Verify only 100 rows comes back on the default search
Pass
 
 2Search for an item using Full-Text Search
Pass
Values searched using standard FTS
 3Change "Company Administration ~> Configuration" Flag: System.Search.RowsToReturn = 1000. Verify only 1000 rows comes back on the default search
Pass
 
 4   

Environment Details

  1. OS version: Win10
  2. Application version: 13.11
  3. Setup on:
    1. Server: LinkQA4
    2. Database: LinkSOFT
    3. LinkSOFT URL: HTTP://
  4. Login Details: Standard username and password for user "admin"

Next Step: Closure


If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L12609 in the subject line of all emails regarding this issue.