Company: Link Technologies
Case No: L09311. Project: 09.40: LinkSOFT Version 9.4
Logged By: Rashna (Edge Business Solutions) on 25 May 2018 02:41PM
Priority: High
Product: Point of Sale
Group: Software Defect
Time Taken: 3.00 (Weight: 3.00)
Version: 9.496.1128
Assigned To: Sanjay (Link Technologies)
Circulation: Alvis, Development, Rashna, Sanjay
Resolve By: Saturday, 26 May 2018 12:00 AM [2155 days since logged date]
Status: Closed
Subject: Unable to edit the "Expiry Days" rule for process "POS025"
Summary:    

Hi Sanjay, 

I have tested the case in 9400 Beta 3.

Issue: There is no option to edit the "Expiry Days" rule for process "POS025". Please add the "Edit" option.

Figure 1: No Edit  Option



Audit Notes:
25 May 201802:43PM Comment 1 by Alvis (Link Technologies) Case 9311 added to project 09.4
28 May 201808:05AM Comment 2 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 28-05-2018 08:05 AM Time Taken: 1.00
Added "edit" ability to the expiry days rule.

04 Jun 201803:51PM Comment 3 by Sanjay (Link Technologies) Assigned To: Rashna (Edge Business Solutions) Followup Date: 04-06-2018 03:51 PM Time Taken: 1.00

System test completed. Verified "Expiry Days" configuration is editable.

regards
Alvis


05 Jun 201812:48PM Comment 4 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 06-06-2018 12:00 AM Time Taken: 1.00
Hi Sanjay,

This case has been successfully tested.

Documentation on the case has been updated :
  • Point of Sales -Web -- Administration -- Processes
Test Environment

  • Version 9400 Beta 4.
  • Database - LINKSOFT on QA1
  • Application on QA1
  • OS - Windows7.

Test Plan 

TestDescriptionStatus
1Users should be able to edit the "Expiry Day"Pass
2Alert should be sent without errorsPass
3

Items A,B and C will appear in the alert with expiry dates as 05/06/2018,06/06/2018 and 07/06/2018 respectively

Pass
4

Item D having expiry date as 16/06/2018 will not populate in the alert.

Pass

Thanks

Rashna


05 Jun 201803:30PM Comment 5 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 05-06-2018 03:30 PM
Thanks Rashna

09 Oct 201908:14AM Comment 6 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019
If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L09311 in the subject line of all emails regarding this issue.

Document size: 4.5 KB