Subject: | User Barcode Login does not work in version 10 |
Summary: | 1. Explain the issue User Barcode Login does not work in version 10 2. Steps to reproduce - Create a new user.
- Enter the security code as 123456 on 222.
- Generate the User Barcode Login card.
- Scan this on POS login to get into the system. Try authenticating the "Search Item".
- Login Fails.
3. Environment Details - Version: 10.0.0.0 BEAT 6
- Setup - Demo
- Server: 10.0.0.10
- Database: LINKSOFT-DEMO-10-RASHNA
|
Audit Notes: | Edited by sanjay on 05/03/19 10:00. |
05 Oct 2018 | 09:32AM Comment 1 by Alvis (Link Technologies) Case 9613 added to project 10.0 |
05 Oct 2018 | 01:48PM Comment 2 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 05-10-2018 01:48 PM Time Taken: 1.00 |
| Development work for this case has been completed. The change will be available in version: 10 beta7 1. The following changes were made(Include Database object names, Program classes and any other relevant information):| - User Login barcode format is: <Login Start Identifier><UserName><SecurityID><Login End Identifier>
- Changed barcode login report to use the above format
- Changed POS Application to use above format
|
|
05 Oct 2018 | 01:49PM Comment 3 by Sanjay (Link Technologies) Assigned To: Rashna (Edge Business Solutions) Followup Date: 05-10-2018 01:49 PM Time Taken: 1.00 |
| System test completed. Proceed with UAT |
|
08 Oct 2018 | 11:32AM Comment 4 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 08-10-2018 11:32 AM Time Taken: 1.00 |
| Hi Sanjay QA Results Tests carried out according to requirements specified on the case header Test Results Summary Table 1 - Summarised list of issues No | Test Description | Pass/Fail | 1 | Set the security ID as 12345678 for user admin. Create the user login card for admin. Scan the card to login into the system | Pass. Further testing completed in case 9617. |
Note: The barcode identifier is case sensitive.
Environment Details - OS version: Windows Server 2012
- Application version: 10 Beta 7
- Setup: Demo
- Server : 10.0.0.10
- Database: UAT-LINKSOFT-DemoData
Steps to reproduce failed scenarios:
Next Step: for closure
|
|
09 Oct 2018 | 10:09AM Comment 5 by Sanjay (Link Technologies) Assigned To: Sanjay (Link Technologies) Followup Date: 09-10-2018 10:09 AM |
| Thanks Rashna |
|
09 Oct 2019 | 08:14AM Comment 6 by Sanjay (Link Technologies) Quality control status: Pass. QC Not required - This case was created before quality check was implemented in version 11 on 30/06/2019 |