Company: Link Technologies
Case No: L11748. Project: 11.40: LinkSOFT Version 11.4
Logged By: Rashna (Edge Business Solutions) on 17 Oct 2019 01:17PM
Priority: Low
Product: Point of Sale
Group: Software Defect
Time Taken: 1.00 (Weight: 1.00)
Version: 11.4.0903
Assigned To: Sanjay (Link Technologies)
Circulation: Development, Rashna, Sanjay
Resolve By: Friday, 27 September 2019 12:00 AM [1647 days since logged date]
Status: Closed
Subject: "Posting Account" and "Cycle Code created in LinkWeb are not seen until the page is refreshed.
Summary:    

Tested in version 11.30

Steps to Replicate

  1. Navigate to Link Web -> Inventory -> Posting Account.
  2. Create a new posting account with code as "DEF" and description as "Default Posting Account".
  3. Save.
  4. The record is not shown on the page." Users need to refresh.

Issue also on this page - ModuleName=Inventory.CycleCode


Audit Notes:Edited by rashna on 17/10/19 13:17. Edited by rashna on 25/09/19 14:05. Edited by rashna on 24/09/19 14:58. 
24 Sep 201902:51PM Comment 1 by Rashna (Edge Business Solutions) Case 11748 added to project 11.004.BETA
25 Sep 201902:05PM Comment 2 by Rashna (Edge Business Solutions) Case 11748 removed from project 11.004.BETA
25 Sep 201902:05PM Comment 3 by Alvis (Link Technologies) Case 11748 added to project 11.004.BETA
29 Sep 201901:43AM Comment 4 by Sanjay (Link Technologies) Assigned To: Development Followup Date: 29-09-2019 01:43 AM

Development work for this case has been completed.

The change will be available in version:11.4.0930

1. The following changes were made(Include Database object names, Program classes and any other relevant information):

  1. Removed caching from Posting Account and Cycle Code forms.

2. Affected Areas:

  1. Posting Account and Cycle Code forms.

3. The issue was caused by:

  1. Cache

4. Notes
5. Next Step
: UAR


30 Sep 201907:55AM Comment 5 by Rashna (Edge Business Solutions) Assigned To: Sanjay (Link Technologies) Followup Date: 30-09-2019 07:55 AM Time Taken: 1.00
QA Results
Tests carried out according to requirements specified on the case header

Test Results Summary

Table 1 - Summarised list of issues
NoTest DescriptionPass/Fail
1Create a posting account as "Main" and save the  record. Record should be updated on the screenPass
2Create a cycle code as "Quart" and save the  record. Record should be updated on the screen
Pass

Environment Details

  1. OS version: Windows Server 2012
  2. Application version: 11.0.0506
  3. Setup: Demo
  4. Server : 10.0.0.14
  5. Database: LINKSOFT-DEMO-11-RASHNA

Next Step

  1. Closure

    17 Oct 201901:17PM Comment 6 by Rashna (Edge Business Solutions) Case 11748 removed from project 11.004.BETA
    17 Oct 201901:17PM Comment 7 by Alvis (Link Technologies) Case 11748 added to project 11.004.BETA
    If you have any queries regarding this support incident, please email admin@linktechnologies.com.au and include the Case No: L11748 in the subject line of all emails regarding this issue.

    Document size: 5.8 KB
    For call complaints, please contact the Managing Director of the company using this form